TM 11-5995-208-24&P-1
CONNECTOR UG-1870A/U REPLACEMENT (CONT)
17. Slide coaxial crimp sleeve (1) over taped coaxial braid (2) and onto coaxial jacket.
18. Remove tape from coaxial braid (2).
CAUTION
When installing coaxial braid clamp assembly (3), be careful not to damage or bend
braid strands.
Make sure braid clamp assembly has been pushed under braid until it meets point where
the braid comes out of trimmed coaxial jacket.
19. Install coaxial braid clamp assembly (3) onto coaxial dielectric.
3-10
|