TM 11-5995-208-24&P-1
CONNECTOR UG-1870A/U REPLACEMENT (CONT)
NOTE
If possible, slide crimp sleeve (6) onto cable jacket when installing it over outer braid
(5). If crimp sleeve will not fit over cabIe jacket, [cave crimp sleeve over outer braid.
14. Install crimp sleeve (6) over outer braid (5), and onto jacket.
Be careful not to damage or bend braid strands when installing braid clamp (7).
NOTE
Braid clamp should be worked gently under outer braid, until it stops where braid comes out
of trimmed cable jacket.
15. Install braid clamp (7) over both coaxial cables.
16. Slide crimp sleeve (8) onto braid (if this has not been done already).
NOTE
Complete all termination steps from 17 through 24 on one coaxial line before terminating
other coaxial line.
|