Click here to make tpub.com your Home Page

Page Title: EQUIPMENT PERFORMANCE DATA
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 11-5995-208-10
EQUIPMENT PERFORMANCE DATA (CONT)
DC Resistance of the Shield (each coaxial cable): 7.5 ohms for each 1320
feet (1/4 mile) of cable when temperature is 68F; 0.9 ohms for
100 feet of cable when temperature is 68F.
Signal Attenuation: CX-11230/G -- 8.5 db per mile at 100 kHz; 38 db per
mile at 2000 kHz; CX-11230A/G (for each 1320 feet or 1/4 mile) -- 2db
at 20 kHz; 9.5 db at 2300 kHz, and 32.0 db at 200 MHz.
Tensile Strength of Cable: CX-11230/G 600 pounds; CX-11230A/G --
1200 pounds.
.
Tensile Strength of Cable-to-Connector Junction: CX-11230/G --
400 pounds; CX-11230A/G -- 350 pounds.
Weight: 8 pounds for 100-foot length and 77 pounds for 1/4-mile length.
Span and Minimum Sag Specification:
WARNING
Be sure you know what the minimum clearance is before you hang your
cable. Your supervisor will give you specific clearance heights before
you start on your cable laying mission.
Do not put cable connectors in the span.
1-12

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business