DIFFERENCES BETWEEN MODELS (CONT)
Cable Assembly, Special Purpose, Electrical CX-11230A/G also has two
conductors, each covered by a plastic insulation, separate shield, and a
plastic jacket. However, the conductors are twisted with plastic and paper
fillers, and secured with a thin, clear plastic. They are shielded again,
wrapped with a thin aluminum, and covered with an outer plastic jacket.
Cable is round in shape and connected at each end with Connector, Plug,
Electrical UG-1870A/U.
Cable Assembly, Special Purpose, Electrical CX-10734/G has two conductors,
each prepared in the same way as Cable Assembly CX-11230/G. Cable is oval in
shape and terminated at one end with Connector, Plug, Electrical UG-1870/U. The
other end is terminated on one conductor with Connector Assembly, Female UG-
1871 /U and on the other conductor with Connector Assembly, Male UG-1872/U.
NOTE
Cable Assembly, Special Purpose, Electrical CX-10734/G is
nonrepairable,
EQUIPMENT PERFORMANCE DATA
TWIN COAX CABLE ASSEMBLIES (CX-11230/G and CX-11230A/G)
Channel Capacity: 6, 12, 24, or 48 channels.
Insulation Quality (each coaxial cable): Can withstand up to 2500 vdc
between center conductor and shield.
Insulation Resistance (each coaxial cable): 50,000 megohms between
center conductor and shield.
Characteristic Impedance: CX-11230/G -- 55 to 65 ohms in frequency
range of 400 kHz to 1000 kHz; 55 to 60 ohms in frequency range of
1000 kHz to 3000 kHz; CX-11230A/G -- to 62 ohms in frequency
range of 500 kHz to 20 MHz.
DC Resistance of Center Conductor (each coaxial cable): 22 ohms for
each 1320 feet (1/4 mile) of cable when temperature is 68F;
2 ohms for every 100 feet of cable when temperature is 68F.