3.19.
TEST SET TS-3760/G IN DIODE MODE
USE OF TABLE 3-3
Table 3-3 gives the 3 possible TS-37601G indicator conditions for the transorb (back-to-back diodes) unit In the circuit
being tested.
Test Set TS-3760/G set up:
Ac power applied.
MODE SELECT SWITCH In DIODE (down) position.
Test lead connected (black to ground, red to circuit being tested).
POWER SWITCH ON.
Push START switch to begin test.
Push RESET switch to stop ALARM (tone or garble sound).
Push RESET upon completion of each circuit test.
TABLE 3-3. TRANSORB (TZ) TEST
Condition
OV Indicator
TK OK Indicator
No.
(Red Light)
(Green Light)
Alarm Sound
Circuit Status
1
On
Off
Tone
Fail
2
Off
On
None
Pass
3
Off
Off
Garble
Fail
3.20.
TEST SET TS-37601G IN SPARK GAP MODE
USE OF TABLE 3-4
Table 3-4 gives the 2 possible TS-3760/G indicator conditions for the spark gap unit in the circuit being tested.
Test Set TS-31601G set up:
Ac power applied.
MODE SELECT SWITCH in SPARK GAP (center) position.
Test leads connected (black to ground, red to circuit being tested).
Push START switch to begin test.
Push RESET to stop ALARM (garble sound).
Push RESET upon completion of each circuit test.
TABLE 3-4. SPARK GAP (SG) TEST
Condition
SG OK Indicator
No.
(Green light)
Alarm Sound
Circuit Status
1
On
None
Pass
2
Off
Garble
Fail