SECTION II. MAINTENANCE ALLOCATION CHART - CONTINUED
(1)
(2)
(3)
(4)
(5)
GROUP
FUNCTIONAL GROUP
MAINTENANCE FUNCTIONS
TOOLS AND
REMARKS
NUMBER
COMPONENT ASSEMBLY
EQUIPMENT
0640
630-MHz band Reject Filter (2A2FL1)
F
See note. Tested at next
(Filter, Band Suppression)
0.5
higher assembly.
F
Visual inspection
0.1
D
32
Cleaning
0.1
D
3, 4, 5, 8, 10, 17,
Test to determine status.
5.0
31, 32. 33, 37,
40, 41, 53, 59,
61. 89, 91
D
Depot disposition
6.0
0642
Wiring Harness, Ac Prime Power
F
F
30, 32, 33
(2A2W46)
0.1
0.5
0641
700-MHz Amplifier (2A2AR1)
F
See note. Tested at next
(Amplifier, Intermediate Frequency)
0.5
higher assembly.
F
Visual inspection
0.1
D
32
Cleaning
0.1
D
3, 4, 5, 7, 8, 10,
Test to determine status.
3.0
13, 17, 27, 32,
33, 41, 53, 55,
61, 69, 71, 72,
78, 89, 97, 112
D
Depot disposition
3.5
0646
Wiring Harness, Frequency Control
F
F
30,32,33
(2A2W38)
0.1
0.5
0648
IF Phase-Locked Oscillator
Same as Group 0224
(2A2Y2) (Oscillator, Radio
Frequency)
C-30