TM 11-5895-833-12/NAVELEX 0967-LP-550-1010/TO 31R5-2TSC54-91
SECTION II. MAINTENANCE ALLOCATION CHART - CONTINUED
(1)
(2)
(3)
(4)
(5)
GROUP
FUNCTIONAL GROUP
MAINTENANCE FUNCTIONS
TOOLS AND
REMARKS
NUMBER
COMPONENT ASSEMBLY
EQUIPMENT
05
CABINET ASSEMBLY
O
Daily and monthly
UP CONVERTER (UNIT 2)
0.4
inspections
O
32
Cleaning
0.4
O
Operational checkout
0.5
O
32
Replacement of fuses
0.2
0510
Blower Assembly (2A11)
O
Monthly inspection
(Fan Assembly, Tubeaxial)
0.1
O
32
Cleaning
0.1
F
32,33
See note. Replacement of
0.7
motor and air flow switch.
051001
Wiring Harness, Ac Power (2A11W2)
Same as Group 011001
0520
Combiner, Microwave Signal (2A12)
O
Monthly Inspection
0.1
O
32
Cleaning
0.3
F
2,3,4,32,33,
See note. Test to de-
1.6
36
termine status.
D
32 thru 35
Replacement to be per-
2.0
formed by depot level
personnel at site. Depot
disposition.
0530
Cabinet Subassembly, Up Converter
F
F
Replace defective cables
0.5
1.5
and harnesses.
053001
Wiring Harness, Ac Power (2W1)
F
F
30,32,33
0.1
0.5