TM 11-5895-833-12/NAVELEX 0967-LP-550-1010/TO 31R5-2TSC54-91
down-converter in the cabinet, slide the
3-10. Up-Converter Input Signal Level
down-converter out of the cabinet, loosen
Change Procedure
the captive screws securing the side cover to
the down-converter, and remove the side
a. Set RF OUTPUT switch to OFF-LINE.
cover. If the filter is changed, make certain
b. Set STATUS SELECTOR switch to 70 MHz IF and
that the placarding on the front of the unit
set IF LEVEL ATTENUATOR switches for center-scale
agrees with the filter installed.
indication on STATUS meter.
c. Observe that the RF LEVEL indicator lamp is
(2) Set POWER ON-OFF circuit breaker to ON and
extinguished.
observe that the POWER ON indicator lamp illuminates.
d. Set STATUS SELECTOR switch to each position in
(3) Set STATUS SELECTOR switch to RF LO
turn and observe the following indications on the
TUNE and adjust RECEIVE FREQUENCY FINE TUNE
STATUS meter:
control for a center-scale indication on STATUS meter.
(4) Set RECEIVE FREQUENCY SELECTOR MHz
Position
Indication
thumbwheel switch to new operating frequency.
70 MHz IF
Blue scale
700 MHz IF
Blue scale
(5) The RF LO indicator lamp will illuminate and the
+ 24V
Green scale
audible alarm sounds when the frequency change is
RF LO TUNE
Red scale
greater than 6 to 10 MHz.
STD LVL
Blue scale
(6) Press and hold AUDIBLE ALARM DEFEAT
RF LO
Blue scale
pushbutton, if necessary, and adjust RECEIVE
IF LO
Blue scale
FREQUENCY FINE TUNE control for a center-scale
indication on STATUS meter.
e. Set RF OUTPUT switch to ON-LINE.
(7) Release
AUDIBLE
ALARM
DEFEAT
pushbutton and note that the audible alarm is silent.
3-11. Up-Converter Output Signal Level
(8) Observe that the RF LO indicator lamp is
Change Procedure
extinguished.
a. Set RF OUTPUT switch to OFF-LINE.
NOTE
b. Set RF OUTPUT LEVEL ADJ to new setting.
Set the MODE SELECTOR switch to
c. Set RF POWER meter upper and lower limit
FM or DGTL, depending upon the re-
controls to position pointers at 1-db points on either side
quired carrier operation.
of new output level.
d. Observe that the RF LEVEL lamp is extinguished.
(9) Set STATUS SELECTOR switch to each
e. Set STATUS SELECTOR switch to each position in
position in turn and observe the following indications on
turn and observe the following indications on the
the STATUS meter:
STATUS meter:
Position
Indication
Position
Indication
+ 24V
Green scale
700 MHz IF
Blue scale
STD LVL
Blue scale
700 MHz IF
Blue scale
RF LO
Blue scale
+ 24V
Green scale
IF LO
Blue scale
RF LO TUNE
Red scale
700 MHz
Approximately 0 to 3
STD LVL
Blue scale
700 MHz
Varies with input signal
RF LO
Blue scale
level (applies to down-
IF LO
Blue scale
converter (wide-band if.)
only)
f. Set RF OUTPUT switch to ON-LINE.
70 MHz IF
Varies with input signal
level
3-12. Equipment Shutdown Procedure
RF LO TUNE
Red scale
Stop the frequency conversion subsystem by turning off
NOTE
all equipment except cesium beam frequency standard.
The 700 MHz IF and 70 MHz IF positions of
the STATUS SELECTOR switch are used
primarily for maintenance caused by the
signal levels required to scale the STATUS
meter in these positions.