1-10. Tabulated Data
0-16568/ C-46().Each Electrical Frequency Synthesizer 0-
a. Frequency Conversion Subsystem.
1658/MSC-46(V)  (frequency  synthesizer)  generates  the
Operating conditions:
standard and variable frequency signals which provide precise
Input power requirements 115 vac, 50 to 400 Hz
frequency control over the local oscillators in the associated
+45F to + 1000F (+ 7.2ƒC to
Temperature
up- or down-converter.
+37.8C)
(9)  Equalizer, Group Delay CN-1425/MSC-46(V).
Elevation
Up to 10, 000 feet above
The Group Delay Equalizer CN-1426/MSC-46(V) (not shown)
sea level.
provides the 50- to 90-MHz linear and parabolic delays
Relative humidity
Tropical conditions including
required to compensate for nonlinearities in equipment
fungus-laden air.
external to the frequency conversion subsystem. The group
Nonoperating conditions:
delay equalizer is mounted external to the frequency
-65ƒF to +155ƒF (-54ƒC
Temperature
conversion subsystem cabinets for optional use when
to +68.40C)
required.
Relative humidity
5% at + 120F (+ 48.9C) or as
(10)  Amplifier, Radio Frequency AM-6631- M.C-
high as 100% from -25F to
46(V.Radio  Frequency  Amplifier  AM-66311  MSC-46(V)
+85F(-31.70C
(distribution amplifier), mounted in the up-converter cabinet,
to +29, 40C) with condensation
receives the 1- and 5-MHz standard frequency outputs of the
at all temperatures lower than
terminal frequency standard and provides four 1-MHz and
+85F (+29, 4C).
twenty-six 5-MHz isolated outputs for distribution to the various
Elevation
Up to 40, 000 feet above sea
frequency conversion subsystem components.
level.
(11) Time base patch panel. The time base patch
Salt atmosphere
As encountered during coastal
panel, mounted in the up-converter cabinet, provides the
service,
`patching facilities required for connecting the 1- and 5-MHz
Transportation
Military transportation methods on
outputs of the terminal frequency standard to the input of the
rail
hydrocushion),
distribution amplifier ((10) above), and the 5-MHz outputs of
highways and
unimproved
the distribution amplifier to the various frequency conversion
roads, and C-130E aircraft.
subsystem components.
b. Down-Conversion Equipment.
(12) If. interface facilities. The if. interface facilities
Input:
located at the top of the frequency conversion subsystem
Frequency band
7.25 to 7.75 GHz.
cabinet, provides the facilities required for connecting the 70-
500 MHz at 0.5 decibels.
MHz inputs and outputs of the ANPrSC-54 modulation and
regference
demodulation equipment to the converters.
Level
43 to - 103 decibels reference
(13)  Access panels.  A single access panel is
to 1 mw (dbm).
mounted at the top of each up- and down-converter cabinet.
Vswr
Less than 1.2:1 over band.
60 ohms.
1-9. Differences Between Subsystem
Configurations
Output:
The main difference between the three configurations of the
Frequency output
70 MHz
frequency conversion subsystem is in the quantity of up-
(Electronic Frequency
converters, down-converters, frequency synthesizers and
Converter CV-1085/
associated blank panels.
The converter and frequency
MSC:46(V))
synthesizer quantities for each configuration are as follows:
Frequency output
70 and 700 MHz
Electronic Frequency
Unit quantities
Converter CV-3085A/
Configu-
Figure
Up-
Down
Frequency
MSC-46(V))
ration
reference
converter
converter
synthesizers
Bandwidth (Electronic
40 MHz
1
1-1(sh1)
2
3
5
Frequency Converter
2
1-1(sh 2)
3
3
6
CV-3086/MSC-46(V))
3
1-1(sh3)
2
2
4
Bandwidth (Electronic
125MHz
Frequency Converter
CV-3085/MSC-46(V))
Level (Electronic
0 dBm 0.5 db for 70 MHZ
Frequency Converter
input signal of.
put signal of - 43 dbm.
CV-3085MSC-46(V))
Level (Electronic
0 dBm + 2.5 db for 700
Frequency Converter
MHz input signal
CV-30856AMSC-46(V))  of - 43 dbm.
Vswr
Less than 1.15:1 from 50 to 90
MHz.
Compression
Less than 0.5 dB at + 10 dbm output.
50 ohms.
If.
700 MHz (special application
with Electronic Frequency
Converter CV-3085/MSC-46V)
Noise figure
16.5 db maximum