TM 11-5895-1179-13 EE132-EA-OMP-010/E106 KY883 TO 31S1-2GSC-161
Table 4-3. Organizational Troubleshooting Chart
WARNING
Set ON/OFF switch to OFF before opening front panel assembly and removing plug-in-circuit card
assemblies.
Item
Checks and
No.
Symptom
Probable Cause
Corrective Action
1
When ON/OFF switch
a. Blown fuse Fl.
a. Check blown fuse indi-
is set to ON, fan
cator. If illuminated,
does not start and
replace fuse Fl
POWER indicator
(paragraph 4-5). If the
does not illumi-
fuse blows again
nate.
replace power supply
plug-in-circuit card
assembly A4 (paragraph
still blows refer to
higher level of mainte-
nance.
b. Primary power is
b. Check connector at
absent.
source input and cable
connection at A5J13 for
tightness.
2
When ON/OFF switch
a. Power supply
a. Set ON/OFF switch to
is set to ON,
plug-in-circuit
OFF. Release the four
POWER indicator
card assembly A4
front panel assembly
does not illumi-
not properly
fasteners and lower the
nate but fan
seated.
front panel assembly.
starts.
Reseat power supply
plug-in-circuit card
assembly A4. Close and
secure the front panel
assembly. Set ON/OFF
switch to ON.
b. Defective power
b. Replace power supply
supply plug-in-
plug-in-circuit card
circuit card
assembly A4
assembly.
4-4
|