TM 11-5895-1179-13 EE132-EA-OMP-010/E106 KY883 TO 31S1-2GSC-161
Table 4-1.
Monthly Organizational Preventive Maintenance Checks and Services
NOTE
If the equipment must be kept in continuous operation, check and service only those items that can be
checked and serviced without disturbing operation; make the complete checks and services when the
equipment can be shut down.
Sequence
Items to be
Paragraph
Number
Inspected
Procedure
Reference
1
Encoder-
Check interior surfaces for
Refer to paragraph
Decoder
rust, corrosion, or fungus.
4-2 if rust,
corrosion, or
fungus is found.
2
Encoder-
Check that equipment is
Refer to paragraph
Decoder
complete.
- 1-3.
3
Encoder-
Check that equipment is
Refer to paragraph
Decoder
properly installed.
- 2-4.
and cables
4
Fan assembly
Check fan assembly A5B1
Refer to direct
for binding and noisy
support mainte-
operation.
nance.
5
Off-line
Perform off-line self-test.
Refer to paragraph
self-test
- 2-6.
6
ERROR RATE
Check for cracks and
Refer to higher
COUNTER
excessive discoloration.
level mainte-
optical
nance.
filter
7
Front panel
Check that front panel
Refer to higher
assembly
assembly fasteners tighten,
level mainte-
the handle is secure, there
nance.
are no dents and the front
panel assembly is not deeply
scratched.
8
Restraint
Check that the restraint
Refer to higher
assembly
assembly is not broken and
level mainte-
is securely fastened.
nance.
9
Clamping
Check that the clamping block Refer to higher
block
is not deformed and is
level mainte-
securely mounted.
nance.
10
Plug-in
Check that plug-in-circuit
Refer to higher
circuit
card assembly ejectors are
level mainte-
card
not missing or broken.
nance.
assemblies
A1-A4