TM 11-5895-1179-13 EE132-EA-OMP-010/E106 KY883 TO 31S1-2GSC-161
Display
Circuit Card
BDl
Decoder Plug-In-Circuit Card Assembly
BD2
Interleaver Plug-In-Circuit Card Assembly
.
BD3
I/O Plug-In-Circuit Card Assembly
BD4
Power Supply Plug-In-Circuit Card Assembly
BD5
Display and Control Circuit Card Assembly
(5)
The electronic signal may sound and an ON LINE FAULT INDICATOR may come on, depending on the cause of
the problem. The off-line self-test stops at this point with the bad circuit card assembly number displayed on the
ERROR RATE COUNTER.
(6)
If no problem is found the off-line self-test runs until T19 is displayed on the ERROR RATE COUNTER. At this
point you can check all the switches on the front panel assembly except the FUNCTION select switch and the
ON/OFF switch, or you can let the off-line self-test run indefinitely.
(7)
If you want to check the front panel assembly switches, you have 5 seconds from the time T19 is displayed on the
ERROR RATE COUNTER to change the position of a front panel assembly switch. The ERROR RATE
COUNTER displays the number of the switch you changed and the position you changed it to. Table 2-7 shows
the ERROR RATE COUNTER display for the individual front panel assembly switches and their positions.
Table 2-7. ERROR RATE COUNTER Display
Switch
Switch
Switch
Name
Number
Position
Display
ENCODER MODE
1
A
1L
select switch
B
1U
C
1R
DECODER MODE
2
A
2L
select switch
B
2U
C
2R
ALARM SET
4
INCREMENT (up)
4U
switch
center
4C
DECREMENT (down)
4D
error rate
5
up
5U
DISPLAY SELECT
center
5C
switch
THRESHOLD (down)
5D
ON LINE/SELF
3
ALARM DISABLE (up)
3U
TEST switch
center
3C
LAMP TEST (down)
3D*
*Changing the ON LINE/SELF TEST switch to the LAMP TEST position (down) during the operator interface test
portion of the off-line self-test causes the off-line self-test to start over from the beginning.
2-16
|