TM 11-5895-1123-34
3-6b above to replace the defective multipin connector.
(3) Place the patch panel in the rack as outlined in
NOTE
paragraph 322 below.
In the next step of this procedure,
h. Replacement of Switches on Subpanel B.
because of the location of the mounting
(1) Remove the TTY/low level patch panel from the
screw, some bending of the contacts on
rack as outlined in paragraph 320 above.
the switch can be expected.
This
(2) Remove the 24 screws on the front panel which
bending shall be kept to a minimum so
hold subpanels A, B, C, and D to the patch panel frame.
that the contacts can be rebent into their
(3) While providing support to the subpanels, set the
proper positions.
patch panel face down with the A and D subpanels
(11) Secure the switch to the panel with the mounting
toward the front.
screw.
(4) Reach under the face of the patch panel and
(12) Lift the subpanels back into the patch panel, and
push the subpanels upward to release them from the
gradually work them back into their positions in the
frame.
frame.
(5) Gradually work the subpanels forward by inching
(13) While providing the subpanels with support, set
the D, A, B and C subpanels forward, in that order, to
the patch panel upside down with the face towards the
face them from the drawer.
front.
(6) Spread the A, B, and C subpanels apart, and
(14) Secure the subpanels to the patch panel by
remove the mounting screw holding the defective switch
inserting and tightening the 24 mounting screws to the
to the subpanel.
face of the patch panel.
(7) Tag and unsolder the wires connected to the
(15) Replace the patch panel in the rack as outlined
defective switch.
in paragraph 322 below.
(8) Pull the defective switch upward and outward to
3-22. Replacement  of  Communications  TTY/Low
remove it from the subpanel.
Level Patch Panel SMA935861 a. Mount the patch
(9) Insert the replacement switch into the subpanel
panel on the slides.
by pushing it inward and downward into place.
b. Connect the three cables to the connectors on
(10) Prepare the wires for soldering and, using good
the rear frame of the patch panel.
soldering practices, solder the wires back to the switch
c. Release the slide latches and push the patch
connections.
panel into the rack.
d. Tighten the four captive screws on the front
panel to secure the patch panel to the rack.
Section VII. MAINTENANCE OF C/N TEST SET TS-3580
3-23. Removal of C/N Test Set TS-3580 Refer to
NOTE
Removal and replacement procedures
3-24. Replacement of C/N Test Set TS-3580 Refer to
for the C/N test set are covered in this
section.
Refer to the appropriate
technical
manual
for
further
maintenance data.
Section VII. MAINTENANCE OF CENTRAL DISTRIBUTION
Frame (CDF) SM-F-935726
3-25. Removal of the Central Distribution
c.
Tag, if necessary, and disconnect the
four cables connected to the bottom of the CDF.
WARNING
d. Loosen the five captive screws fastened along
Two persons are required to perform
the bottom holding it to the rack frame.
this procedure due to the bulk of the
e. While supporting the CDF, loosen the five
unit.
captive screws along the top edge holding it to the rack
a. Turn off the ac power to the CSS.
frame.
b. Tag, if necessary, and disconnect the four
cables connected to the top of the CDF.
3-47