T.O. 31'W2-2GSC24-2
TM 11-5805-688-14-1
NAVELEX 0967-LP-545-3010
SECTION II
SPECIAL MAINTENANCE
supplemental manual T.O. 31W2-2GSC24-2-1 which is
6-43.
INTRODUCTION.
authorized for depot use only. The detailed instructions
for removing and installing the plug-in cards and the
6-44. This section provides instructions and data
power supply are contained in section I of this manual.
applicable to special and depot maintenance of the
multiplexer set. Included are procedures for repair of
6-49.
MAINTENANCE SUPPORT EQUIPMENT.
backplane assembly connectors, and semipermanently
mounted chassis mechanical parts. Repair of the power
supply and the plug-in cards is performed at a depot
facility as prescribed in paragraph 6-48.
in support of the multiplexer set at the special
maintenance level.
Brief summaries of pertinent
6-45. Aside from certain specific areas discussed in
performance characteristics are also provided. Special
maintenance support equipment items that are also used
this section, special maintenance practices performed on
at the organizational/intermediate maintenance levels are
the multiplexer set are consistent with those applicable to
listed and described in table 6-1. The items listed in
other military electronic equipment.
Personnel
performing special maintenance should have a high
maintenance.
Items having equivalent (or greater)
degree of familarity with these practices, as well as a
functional capabilities, however, may be substituted
thorough understanding of the multiplexer set theory of
when necessary.
operation.
6-51 THROUGH 6-64. DELETED.
6-46.
GENERAL.
6-47. Repair of the multiplexer set at the special
6-65.
CONNECTOR REPAIR.
maintenance level generally entails correction of those
malfunctions that are beyond the scope of the
6-66. Except for the connectors forming a part of the
organizational and intermediate levels.
The tasks
backplane wiring assembly,
the connectors used
include repair of the structural components and electrical
throughout the multiplexer set are conventional types
connectors in the multiplexer set.
common in most military electronic equipment.
Connectors not associated
6-48. The testing, troubleshooting, and repair of the 12
plug-in cards and the power supply are performed at a
depot facility. The detailed procedures are contained in
Change 2 6-42
|