5-588. When the output from AND gate U22 is high (no-
applied to one input of an exclusive OR gate. The
error condition), AND gate U36 is enabled.  The low
diagnostic error signals applied to the display card are
output from AND gate U36 is applied as an enable signal
high-level in- puts in the no-error condition and be- come
to the lamp display decoder logic that causes signal RBI-
low-level inputs in the error condition. Self-test signal
to be generated and applied to the front pan- el. In a no-
ST2- is applied to the other inputs on the exclusive OR
error  condition,  signal  RBI-  causes  the  FAULT
gates. In normal operation, signal ST2- applied to the
LOCATION display on the front panel to show 00. The
display card is a high- level input. In the self-test mode
lamp display logic decoder also generates an indicator
of operation, signal ST2- becomes a low- level input.
enable signal to the front panel that causes all the
Each exclusive OR gate produces a low-level output
indicators to light in a no-error condition.
signal when both inputs are the same: both inputs either
high or low. The OR gate produces a high-level output
5-589. When one or more of the applied error signals
signal when the two inputs are different: one high and the
from the functional cards indicate a fault during the self-
other low. In the following discussion, the circuits on the
test mode, the self-test logic function that is performed is
display card are described in their normal operating
basically the same as described in the preceding
mode.
paragraphs; with two exceptions. The primary diagnostic
circuits cancel the 00 display function and the FAULT
5-593. Multiplexer positive stuff acknowledge signal
LOCATION display shows a defective card number
MPSA- from the OEG card conveys the diagnostic error
between 1 and 21.  Also, the appropriate MULTI-
status for one multiplexer channel card during word 24.
PLEXER CARD or DEMULTIPLEXER CARD indicator
In a no-error condition, signal MPSA- is high and
on the front panel goes out.
becomes low in an error condition. Flip-flop U17-6 in the
multiplexer channel card error detector circuit produces a
5-590. When all the functional cards are in a no-error
clock pulse to counter U8 when low-level signal MPSA-
condition and an error condition is detected in the
and word 24 end-of-scan signal M24EPS2 from the OEG
diagnostic circuits on the display card, the output from
card are applied at the same time.  At the time that
the card address self-test OR function circuit goes high.
counter U8 receives a clock pulse, the channel over-
Therefore, the output from AND gate U22 goes low. The
head address count signals (MOHO through MOH3) for
low-level signal enables the count 22 override circuit so
the card being sampled is parallel loaded into U8. The
that the FAULT LO- CATION display on the front panel
overhead address loaded into U8 is applied to the 12
shows 22. Also, the low-level input to the lamp display
inputs of multiplexers U3 through U6 in the card address
decoder logic generates signal LMCRD that causes the
encoder circuit. The low output from U17-7 is applied as
MULTIPLEXER CARD indicator on the front panel to go
an error signal to system priority encoder U7. If there are
out.
no other error inputs with a higher priority being applied
to encoder U7, the encoder produces the 010 address
select signals that are applied to multiplexers U2 through
5-591. DETAILED
FUNCTIONAL
CIRCUIT
U6.This  address  enables  the  T2  input  of  each
DISCUSSION.
multiplexer so that the dynamic and hard-wired card
address at the 12 inputs of multiplexers U3 through U5 is
5-592. Each card diagnostic error signal applied to the
applied to binary-to-BCD converter U12.
display card, except the out-of-tolerance inputs, is
5-160