REMOTE ALARM OPTIONS
Signal
Pin No.
Function
3.96.2. There are seven remote alarm signals routed to
the REMOTE ALARM connector on the rear panel. The
LERRC2
J66-H
duces fault indication
remote alarm signals that are applied to the REMOTE
during time that bit
ALARM connector are initiated by the multiplexer set
error
rate
in
a
diagnostic circuits. The diagnostic circuits automatically
demultiplexer exceeds
monitor the equipment for faulty system data inputs and
a
preselected
multiplexer set equipment malfunctions.  Each of the
threshold.
remote alarm signals is associated with a pair of outputs
OOTC1
J66-N
System indicator - Pro-
(C1 and C2) that are held in an open-circuit condition in a
OOTC2
J66-P
duces fault indication
no-error condition.
When a fault is detected, the
when
an
out-of
associated pair of outputs is closed in the multiplexer set
tolerance
condition
to produce a closed-loop output condition. The seven
exists  between  the
remote alarm signals and their associated output pin
incoming data and one
locations on the REMOTE ALARM connector are listed
multiplexer
input
below.
Connector kit assembly 61867000-009 or
circuit.
6187000-019 contains the mating connector for the
FAILC1
J66-E
Multiplexer set indica-
REMOTE ALARM connector.
FAILC2
J66-F
tor - Produces fault
indication when a card
malfunction
in
Signal
Pin No.
Function
multiplexer
set
is
detected.
LOFAC1
J66A
System indicator - Pro
PSFC1
J66-L
Multiplexer set indica-
LOFAC2
J66B
duces fault indication
PSFC2
J66-M
tor
Produces fault
during
time
that
indication when power
demultiplexer circuits
supply malfunction in
are not synchronized
multiplexer
set
is
with incoming data.
detected.
LOFBC1
J66-C
System indicator - Pro
TEMPC1
J66-J
Multiplexer set indica-
LOFBC2
J66-D
duces a continuing
TEMPC2
366-K
tor  Produces  fault
fault indication once
indication
when
demultiplexer circuits
internal
operating
are not synchronized
temperature
in
with incoming data.
multiplexer
set
205F
Fault indication re-
exceeds
(96C).
mains until DISPLAY
RESET  switch  is
pressed
on
multiplexer set.
3-97. MULTIPLEXER SET OPERATIONAL
LERRC1
J66-G
System indicator - Pro
TESTS.
3-98. When a multiplexer set is reconfigured for a different
system application, the performance standards prescribed
in paragraph 6-38 will be performed. These procedures
will also be performed when a multiplexer set is initially
installed in a system to ensure that the equipment is
operationally ready to perform its assigned tasks.