Table 6-11. Processor Interrupt Test Error Definitions (cont)
TYPE OF
ERROR
DEFINITION
8
Non-continuous
Execution
9
Interrupt Code Error
A
Program Counter Error
6-28. LF CLOCK AND POWER FAIL TEST
Where xx indicates the test number in
ERROR PRINTOUTS. If an error is detected
which the error was detected, yyyy indi-
cates the program address where the error
during the LF Clock and power fail test,
occurred, and z indicates the type of
the TTY will type a standard error message
error. See table 6-12 for definitions of
in the following format:
test numbers and table 6-13 for definitions
of types of errors.
T xx A yyyy B z
Table 6-12. LF Clock and Power Fail Test Number Definitions
DEFINITION
TEST NUMBER
Line Frequency Clock Test
01
Power Fail/Restart Load Core Memory with FFFF 16
02
Test
Power Fail/Restart Load Core Memory with 0000 16
03
Test
Power Fail/Restart Clear Core Memory Test
04
Table 6-13. LF Clock and Power Fail Test Error Definitions
TYPE OF
DEFINITION
ERROR
Status Error
0
Data Error
1
Timing Error
2