Page Title: Table 4-1. Controls and Indicators (Cont'd)
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

T.O. 31S5-4-308-1
TM 11-5805-663-14-13
NAVELEX 0967-464-0010
Table 4-1. Controls and Indicators (Cont'd)
FUNCTION
TYPE
NAME
Register
Switch
register 0
through 15
Instruction Register
9
(Cont'd)
Firmware A
10
(address of last instruction)
Firmware B
11
(operand effective address)
12
Not assigned
Not assigned
13
Not assigned
14
Control Register
15
The selected register can be accessed by touching the
register read or write indicator switch. Following a
system reset or after power is turned on, register 0
is always selected.
Touching the switch turns on its indicator, and the
Touch response
address
data displayed on the data indicators is written
write
indicator switch
into the selected CPU or system processor address.
If done indicator remains on, access was
successful.
This indicator switch operates nearly the same as the
address
Touch response
register read indicator switch, except that the data
read
indicator switch
displayed in the data indicators is read at the
address displayed by the address indicators.
The first touch of the switch does not increment the
address indicators before accessing the address.
However, all following successive touches of the
I
switch increments the address indicators by 2 be-
fore the access. Touching any other switch but the
register or data switches before touching the read
switch prevents the address indicators from being
incremented prior to the access.
address 0
Touch response
The address switch indicators 0 through 15 select
through 15
indicator
the address to be accessed whenever the address
switches
read or write switch is touched. On indicators
represent binary ONES: off they represent binary
ZEROES. Each switch has toggle action, that is,
if the first touch of any switch turns the indicator
on, the second touch turns the indicator off, and
vice versa. After touching reset or after power is
turned on, the switch indicators are always cleared
to 0000 16.