CHAPTER 1
THEORY
Section I. GENERAL
this equipment includes TM 11-4940-204-12 and TM 11-
1.
Scope
4940-204-15P.
a. This manual covers field and depot maintenance
c. Forward comments concerning this manual to
for Degreaser MX-1760/G (degreaser).
It includes
the Commanding Officer, U.S. Army Signal Materiel
instructions appropriate to third, fourth, and fifth echelons
Support Agency, ATTN: SIGMS-PA2d, Fort Monmouth,
for testing and repairing the equipment and replacing
N. J.
maintenance parts. It also lists tools, materials, and test
Note:
equipment  for  third,  fourth,  and  fifth  echelon
maintenance. Detailed functions of the equipment are
For applicable forms and records, see
covered in paragraphs 3 and 4.
paragraph 2, TM 11-4940-204-12.
b. The
complete
technical
manual
for
2.
Index of Equipment Publications
Refer to DA Pamphlet 310-4 to determine what
changes to or revisions of this publication are current.
Section II. MECHANICAL AND CIRCUIT THEORY
b. Ac Motor (fig. 1). The 5.7-ampere reversible
3.
Mechanical Theory
alternating current (ac) motor used in the degreaser
requires single phase, 115-volt, 60-cycle-per-second
Degreaser MX-1760/G contains a centrifugal pump (a
power for operation.
The motor is rated at 1/3
below) which draws Cleaning Compound (Federal stock
horsepower at 1,725 revolutions per minute (rpm). A 4-
No.  7930-396-3420) from an integral reservoir and
inch single-grooved pulley for a V-belt is mounted on the
sprays the cleaning compound under pressure against a
motor shaft.
turntable which is free to rotate. The cleaning compound
c. Electrical Switch Timer (fig. 1). The electrical
loosens grease and dirt from parts placed on the
switch timer consists of a clock mechanism and contact
turntable and the force of the spray rinses the parts
points. The electrical switch timer operates the ac motor
clean.  The centrifugal pump is driven by an electric
for a selected time period of up to 30 minutes maximum.
motor (b below) that is controlled by an electrical switch
If the automatic cutoff feature is not desired, the
timer (c below).
electrical switch timer consists be manually operated to
Warning:
the HOLD position, as long as necessary, by the rotation
Cleaning compound is flammable and
of the control knob, and then to the 0 position for cutoff.
its fumes are toxic. Do not use near a
flame; provide adequate ventilation.
4.
Circuit Theory
a. Centrifugal Pump (fig. 3). A centrifugal pump is
used to build up pressure. The impeller draws cleaning
The ac input power is applied from one terminal of
compound from the reservoir through the intake of the
Connector Plug UP-121/M to terminal 1 of the electrical
casing (22), and applies it under pressure through the
switch timer, through the switch contacts to terminal 2
outlet (23) to the sprays.  A conventional stuffing box
packed with graphite-impregnated asbestos forms a seal
between the shaft and the casing.