TB 9-289
h. Alternate methods such as trace gas testing or variations on the 12 hour pressure retention test may be submitted
for review to:
Commander
U.S. Army Tank-automotive & Armaments Command
AMSTA-IM-OEM
Warren, MI 48397-5000
7. REFINISHING PROCEDURES
WARNING
UNUSABLE CARC PAINT
Unusable CARC Paint mixtures may be considered hazardous waste and require
disposal in accordance with Federal, State, DOD and DA hazardous waste
regulations. Consult the installation environmental office for proper disposal
guidance. Mixed CARC paint has a flashpoint of approximately 38 F (3 C) due to
the incorporation of solvents and is highly flammable.
HEATING CARC PAINT
Heating cured CARC paint above 400F (204 C) may cause medical injury. Do not
heat CARC paint in excess of 400 F (204 C)
CARC PAINT PROTECTION
Use impervious gloves (not cloth) when mixing or applying CARC paint. Avoid
skin contact and vapor inhalation
NOTE
Container interiors/exteriors will not be completely stripped and repainted for
cosmetic reasons, except for FMS customers. Mask all decals prior to initiation of
the following procedures.
a. Prime and paint interior and exterior metal surfaces of containers that have had finish removed during cleaning or
repair. Apply CARC paint in both spot painting and total refinishing.
b. Clean method I or III in accordance with TT-C490.
c. Treat (pretreatment) per Type I or III of TT-C490.
10
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |