STEP 17
REMOVE POWERPLANT.
Disconnect
harness
11655456
connectors
from
generator.
Perform continuity checks between harness 11 655456
connectors  at  generator  and  engine  disconnect
connector per chart V.
a. If continuity does not exist, repair harness
11655456
b. If continuity exists per chart V, generator is
defective Replace generator.
CHART V
Engine
To
Disconnect
Generator
Accessory
From
11655456
Connectors
Connector
Pin
Connector
Pin/Socket
11655456
Pin J
(Circuit 1)
Field (J2)
Socket C (Generator Top)
11655456
Pin L
(Circuit 534)
AC (J1)
Pin B (Generator End)
11655456
Pin C
(Circuit 533)
AC (J1)
Pin A (Generator End)
18