3 BATTERY-GENERATOR
INDICATOR INDICATES GENERATOR IS OVERCHARGING WITH
POINTER IN RIGHT RED
a.
If 25 to 30 VDC exists, refer to TM 9-2350-257-
With engine running, check for 25 to 30 VDC at slave
20-1 troubleshooting procedures for the battery-
receptacle.
generator Indicator.
NOTE
b.
If more than 30 VDC exists, proceed to
The center connection of the slave
TROUBLESHOOTING PROCEDURE, step 1.
receptacle is positive (+) when
measured to vehicle chassis (GROUND)
NOTE
Both the RISE and RISE passive
harness number is shown in the
NOTE
troubleshooting procedures which follow
When removing or replacing connectors,
The RISE passive harness number is
a spanner wrench must be used to avoid
in parenthesis adjacent to the RISE
damaging connector shells.
harness number.
For ex- ample
harness 11673839 (11655747)
At the completion of the following
battery-generator-regulator
troubleshooting
malfunctions
procedures, ensure that all wiring
harnesses,
cables,
and
other
components have been reconnected
and secured