TB 9-2350-257-20-1
I. PRELIMINARY CHECKS
1 BATTERY-GENERATOR INDICA- TOR POINTER IN THE LEFT RED AREA WITH ENGINE NOT
RUNNING.
Place MASTER BATTERY switch in OFF position
a.
If yes, refer to TM 9-2350-257-20-1
Check If specific gravity of batteries is above 1 225
troubleshooting procedures for the battery-
generator indicator.
b.
If no, charge batteries, and clean and tighten
battery connections
2 BATTERY-GENERATOR INDICATOR POINTER IN YELLOW AREA WITH ENGINE RUNNING
With engine running, check for 25 to 30 VDC at slave
a. If 25 to 30 VDC exists, refer to
receptacle.
TM 9-2350-257-20-1 troubleshooting
procedures for the battery-generator
indicator.
NOTE
b. If less than 25 VDC exists proceed to
The center connection of the slave
TROUBLESHOOTING
PROCEDURE
receptacle is positive (+) when
measured to vehicle chassis (GROUND)
Do not touch probe against outer case
because of possible short to ground
5
|