SB 740-95-10
Quality
Quality
Defect
Defect
Code
Explanation
Code
Explanation
22
Excessive weight or cube for containers.
50
Contamination (contains dirt, sludge, moisture, or
23
Containers, boxes, crates, or pallets damaged or
other foreign matter).
deteriorated.
51
Excessive moisture, fungus, mildew, rot, infestation,
24
Intermediate or exterior container protection not
or weather cracks.
compatible with mode of shipment, type of storage,
52
Item improperly classified.
destination, or other environment.
53
Test or research required to determine true
25
Wrong level applied.
condition classification (assign code J or code K, per
26
Containers, boxes, crates, or pallets do not meet
AR 725-50). (Chargeable as one minor defect per
specifications.
line item.)
27
Wrong quantity per intermediate or exterior
54
Materiel marking missing or incorrect (e.g., serial
container. (Chargeable as one defect per container.
number, data plate, piece mark, or cure date).
Major defect, if shortage-minor defect, if overage.)
(Chargeable as minor defect if correct item shipped
28
Reserved for future use.
and major defect if wrong item shipped.)
29
Reserved for future use.
55
Shelf-life date exceeded.
56
Wrong item received or selected for shipment.
(d) Group 3 (marking and labeling).
57
Lubrication improper or incomplete.
Quality
58
Improper identification.
Defect
59
Other.
Code
Explanation
(g) Group 6 (functional, certification, or
30
Preservation, and packing (PIP) level markings
omitted, illegible, or incorrect.
performance test).
31
Labels omitted, illegible, or incorrect.
Quality
32
Special markings omitted, illegible, or incorrect.
Defect
33
Description or identification marking omitted,
Code
Explanation
illegible, or incorrect (e.g., stock number, quantity,
60
Required test not accomplished.
unit of is- sue, contract data, or condition code).
61
Failed test requirements (hydraulic).
34
Address marking omitted, illegible, or incorrect.
62
Failed test requirements (electrical or electronic).
35
Markings improperly located or wrong method of
63
Failed test requirements (environmental).
marking used.
64
Failed test requirements (mechanical).
36
Reserved for future use.
65
Failed test requirements (pressure).
37
Reserved for future use.
66
Failed certification or laborator y test.
38
Reserved for future use.
67
Excessive heat or noise during operational test.
39
Reserved for future use.
68
Parts or components damaged (caused by
(e) Group 4 (materiel deficiencies).
functional failure during end item or component
Quality
test).
Defect
69
Reserved for future use.
Code
Explanation
(h) Group 7 (document, recording, or
40
Parts, components, or controls loose, improperly
routing deficiencies).
installed or assembled, out of adjustment, do not fit,
Quality
or fail to function properly.
Defect
41
Damaged or defective item or parts (bent, broken,
Code
Explanation
scratched, chipped, marred, cracked, warped, torn,
70
Wrong count (shortage). (Chargeable as one major
stripped, crimped, burned, twisted, burned out,
defect per line item if value of quantity short is $200
perforated, or pitted).
or more and minor defect if less then $200.)
42
Does not meet specified tolerances or requirements
71
Wrong count (overage). (Chargeable as one major
(dimensional, finish, strength, torque, output,
defect per line item if value of quantity over is $200
volume, color, stretch, size, illumination, or weight).
or more and minor defect if less than $200.)
43
Parts or components missing.
72
Improper routing or process planning. (Chargeable
44
Wrong part or component found installed on end
as one minor defect per line item.)
item or other assembly, or used to make up set or
73
Mixed materiel (two or more stock numbers
kit.
recorded under the same stock number).
45
Leak (liquid): gasoline, diesel, oil, water, etc.
(Chargeable as one minor defect per line item.)
46
74
Historical records, including The Army Maintenance
etc.).
Management System, TM 38-750, missing,
47
Modification work order incomplete, improperly
incorrect, or incomplete.
applied, or missing.
75
Contract, specifications, receiving reports, or other
48
required documents incorrect, incomplete, not
defect.
available,
or changes not with the contract.
49
Reserved for future use.
(Chargeable as one minor defect per line item.)
(f) Group 5 (materiel deficiencies-continued).
2-3
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |