SB 740-91-01
TEST PROCEDURE .020
Gun Direction Unit
1. General
This procedure provides a description of special test equipment, fixturing, cabling, instrumentation, and instructions for
performing the inspection and evaluation applicable to Gun Direction Unit OD-144/GYK-29.
2. Test Equipment/Test Setup
All Tests are to be performed under the following environmental conditions, unless otherwise stated:
20+ 10C (73 + 18F)
Temperature:
Relative Humidity:
80 percent maximum.
All test equipment is to be energized for at least 30 minutes prior to utilization, unless otherwise specified in operating
manual for test equipment.
All tests are to be performed in an electromagnetic shielded enclosure, if in a high RF field of interference.
Table B-l lists the test equipment and Figure B-l illustrates the test setup.
Table B-1.Test Equipment for Procedure
Item
Technical Manual (Ref.)
Oscilloscope, Hewlett-Packard, Model 181A
NA
Digital Multimeter, Fluke, Model 8050A
NA
Signal Generator, Hewlett-Packard, Model 3310A
NA
Counter timer, Hewlett-Packard, Model 5315B
NA
Floodlamp, Commercial
NA
Power Supply One (PS1) Hewlett-Packard, Model 6269B
NA
Power Supply Two (PS2) Hewlett-Packard, Model 6269B
NA
Multimeter, AN/PSM-6
NA
Resistor, 6k ohm
NA
Resistor, 600 oh
NA
Change 1 B-130.16
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |