SB 740-91-01
Insulation Resistance
(for wire length
Wire Size and
0-100 ft, 60'-82-F)
Configuration
megohms
#14 and smaller
500
#12 and larger
100
Junction-boxes
100
and patch plugs
Coaxial cable--
500
Inner to outer
conductor
(3) Testing shall be done at temperatures between 600 and 820F. If wiring is tested above 820F, the minimum
acceptable resistance requirement (see table above) shall be reduced by 2 percent for every Fahrenheit
degree above 82'F. If wiring is tested at a temperature below 600F, the minimum acceptable resistance
requirement (see table above) shall be increased by 2 percent for every Fahrenheit degree below 600F.
(4) Allowance should be made to compensate for the electrical characteristics of test instrumentation, including
harnesses.
(5) Reject wiring which does not meet the insulation resistance requirements.
B-12
|