TM 5-3655-214-13&P
4-9. GUARDS - Continued
Materials/Parts
General Safety Instructions
Approved cleaning solvent,
Observe Warnings
P-D-680 or equivalent
and Cautions
Bristle brush
Personnel Required
MOS 52C
LOCATION/ITEM
ACTION
REMARKS
REMOVAL
WARNING
Make certain that pump has been shut down and electrical power disconnected.
1. Guard
a. Refer to illustration at the end of this
section.
b. Remove pump guard (4).
c.
Remove six screws (5), six flat wash-
ers (6) and six lockwashers (7)
attaching belt guard (8).
REMOVAL
1.
Guard
(Continued)
d.
Remove belt guard
WARNING
Dry cleaning solvent, P-D-680 or P-S-661, used to clean parts is potentially
dangerous to personnel and property. Use in a well-ventilated area as the fumes
are dangerous if inhaled. Avoid repeated and prolonged skin contact. Do not
use near open flame or excessive heat. Flash point of solvent is 100F. - 138F
(38C. - 59C.)
4-8