Click here to make tpub.com your Home Page

Page Title: Section II. TROUBLESHOOTING
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 5-3655-214-13&P
Section II. TROUBLESHOOTING
3-2. TROUBLESHOOTING TABLE
a. This section lists the common malfunctions which may occur during operation of the recharging unit.
b. This manual cannot list all malfunctions that may occur. If a malfunction is not listed or is not corrected by listed
corrective actions, notify your supervisor.
TROUBLESHOOTING TABLE
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. MOTOR DOESN'T START.
Step 1. Check electrical connection.
Correct as required.
Step 2. Motor or Cable defective.
Refer to organizational maintenance for replacement.
Step 3. Starter damaged or defective.
Refer to organizational maintenance for repair or replacement.
2. MOTOR AND PUMP OPERATE, BUT FLUID DOES NOT FLOW.
Step 1. Check that the supply valve and the discharge shut off valve are in the open position.
Open valves as required.
Step 2. Check that the inlet bleed valve and the discharge blow-off valve are in the closed position.
Close valves as required.
Step 3. Slightly open inlet ble ed valve to permit visual check that the supply cylinder contains fluid.
Replace supply cylinder if fluid is not discharged from the inlet bleed valve.
Step 4. Inspect Tailpiece filter for clogged or damaged condition. See Section III.
Clean or replace filter as directed see in Section III.