TM 5-3610-254-14
4-23. VERTICAL CAMERA AND VACUUM PUMP MAINTENANCE INSTRUCTIONS (cont)
LOCATION
ITEM
ACTION
REMARKS
INSTALLATION
5. Vacuum Pump
a. Screws (4), lock-
Install.
washers (5), and
mounting plate (6)
b. Screws (1), lock-
Install.
washers (2), and
flat washers (3)
c. Power cord
Connect to proper
and vacuum
receptacle.
hose
This task covers:
a. Inspection
b. Removal
c. Repair
d. Installation
LOCATION
ITEM
ACTION
REMARKS
INSPECTION
1. Darkroom
Lamp filters
Check that filter covers
lamp.
Check for cracks
or tears in filter.
2. Light
a. Fluorescent tubes
Check for discoloration,
Fixture
inadequate illumination,
and failure.
b. Tube socket
Check for security and
damage.