TM 5-3610-254-14
Table 4-1. ORGANIZATIONAL PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS)
Legend
M - Monthly
Q - Quarterly
S - Semiannually
ITEM
INTERVAL
ITEM TO BE
NO.
INSPECTED
PROCEDURE
MQ
S
5
Film Dryer
Inspect dryer for general condition and
security of mounting. If inspection
indicates that replacement of the dryer
is necessary, refer to paragraph 4-25.
6
Vertical Vacuum
Inspect vacuum frame for security and
Frame
condition of glass and lights. If
inspection indicates that replacement of
the vacuum frame is necessary, refer to
7
Vertical Vacuum
Inspect vacuum pump for security and con-
Frame Vacuum
dition. If inspection indicates that
Pump
replacement of the vacuum pump is neces-
sary, refer to paragraph 4-30.
8
Wall Mounted
Inspect viewing light for general condi-
Viewing Light
tion and security of mounting. If
inspection indicates that replacement of
the viewing light is necessary, refer to
9
Pin Point
Inspect light assembly for security of
Light Source
mounting. Inspect light assembly casing
Assembly
for damage. Inspect power cord and timer
for proper operation. Inspect bulb for proper
operation. If inspection indicates replacement
of the light assembly is necessary, refer to
10
Phototypesetter
Inspect processor assembly and shelf for
Processor
general condition and security of mount-
Assembly
ing. If inspection indicates that
replacement of the processor is neces-
sary, refer to paragraph 4-33.
4-14
|