TM 5-3610-254-14
Table 3-1. OPERATOR TROUBLESHOOTING (cont)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Step 2. Check to see if the main power cable leads are properly connected at generator.
The leads of the power cable are color coded as follows:
L1 - black - Pin 1
L2 - red - Pin 2
Ground - green (marked with blue band) - Pin 3
L0 - white - Pin 4
Step 3. Inspect to see that the generator is operating properly.
Start the generator set in accordance with the
applicable Department of the Army Technical Manual.
Step 4. Inspect to see if main breaker is in the ON position. Position applicable circuit breaker to ON.
2.
NO ELECTRICAL POWER AT EQUIPMENT RECEPTACLES
Inspect to see if main circuit breaker is in the ON position.
Position applicable circuit breaker to ON.
3.
LIGHT TABLE WILL NOT ILLUMINATE
Check for defective fluorescent tube.
Replace defective fluorescent tube as described in paragraph 4-19.
4.
CAMERA VACUUM COPYBOARD INOPERATIVE
Using foot pedal, operate vacuum pump and check for leaks from vacuum
hose extending from pump to underside of copyboard.
Disconnect defective hose at pump and copyboard and replace
hose as described in manufacturers manual.
3-3
|