Table 3-2. Functional Test Procedures (Cont)
Test
No.
Test
Procedure
4
Remote Alarm
a.
Connect jumper wire between socket D and E
Signal
of connector.
CONNECTOR
b.
Disconnect multimeter positive (red) lead
from test set, test point A.
c.
Set multimeter to 10 volt dc scale.
d.
Connect multimeter positive (red) lead to
TEST SET test point B.
Power ON.
e.
f.
Read multimeter. If it reads between 4.5 and
6.5 volts, continue testing. If it does not,
refer to Troubleshooting paragraph 3-7.4.
Power OFF.
g.
Remove jumper wire and disconnect multimeter
h.
leads.
i.
Disconnect cable from input power connector.
If used, unplug power supply from ac power
j.
source, and set aside.
Change 2
3-18