ARMY TM 3-6665-329-13&P
AIR FORCE TO 11H2-18-1
Table 3-2. Functional Test Procedures (Cont)
Test
Procedure
Test
No.
a.
Set multimeter to 50 volt dc scale.
11 volt supply
b.
Connect multimeter positive (red) lead to
test point A and negative (black) lead to
test point D.
Power ON,
c.
Read multimeter. If it reads between 10 and
d.
12 volts, continue testing. If it does not,
refer to Troubleshooting, paragraph 3-7.4.
Power OFF.
e.
3-17
Change 2
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |