2-26. CABLE C5-19-6691 - MAINTENANCE INSTRUCTIONS.
This task covers:
c. Replace
a. Removal
d. Installation
b. Test
INITIAL SETUP
Test Equipment
Multimeter AN/USM223
ACTION
ITEM
LOCATION
REMOVAL
WARNING
High voltage is used to power this equipment. Before removing power cable, be sure that POWER
switch on compartment control module is in the OFF position and that the collective protection
equipment power source is shut down to avoid personal injury or loss of life.
Set compartment control module POWER switch (1)
Cable C5-19-6691
Power Distribution Unit
to OFF.
and Power Source
Connector
Shut down collective protection equipment
power source.
Disconnect cable assembly plug P7 (2) from power
distribution unit connector J7 (3).
Disconnect cable assembly plug PI 2 (4) from power
source connector (5).