TM 3-4240-284-20&P
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) SEMIANNUAL SCHEDULE
NOTE
Perform these checks and services in the order listed before you perform functional testing.
Item To Be
Item
Inspected
Procedures
No.
Filter Housing
1
Inspect identfication and instruction plates. You must be able to read
them. Replace plates if necessary (p 2-77 and p 2-78).
Inspect outside surfaces for rust, chipped paint, or bare metal on painted
surfaces. Repaint or touchup as necessary (p 2-78).
Make sure that all parts are secure and that there is no loose or missing
hardware. Tighten loose hardware. Replace missing hardware.
Inspect cable assemblies for bare wires, broken insulation, broken or
Special Purpose
2
damaged connectors. Replace damaged cable assemblies (p 2-95 through
Electrical Cable
2-106).
Assemblies
Inspect cable assembly for bare wire, broken insulation, broken or
Main Fan Assembly
3
damaged connector. Replace damaged main fan assembly (p 2-79).
Cable
Airflow Valve
4
Inspect valve for damage and loose mounting hardware. Replace missing
mounting hardware. Replace damaged airflow valve (p 2-82).
Inspect unit for loose or missing mounting hardware. Tighten loose
Power Distribution
5
hardware. Replace missing hardware.
unit
Inspect for damaged or missing electrical covers. Replace power distribu-
tion unit if the covers are damaged or missing (p 2-85).
Gas-Particulate
6
WARNING
Filters
DO NOT throw away damaged
or unusable filters as
ordinary trash.
D O turn in damaged or unusable
filters to your hazardous
w a s t e management office or
Defense Reutilization and
M a r k e t i n g Office (DRMO).
Remove fiters (p 2-70) and check for physical or water damage.
Inspect housing seal and inner cover gasket for damage. Replace seal or
gasket if unserviceable (p 2-71).
Reinstall filters or install new filter (p 2-72).