2-16. PUMP UNIT SUBASSEMBLY (CONT).
REMARKS
ACTION
LOCATION/lTEM
REASSEMBLY
(CONT)
Pump Unit Subassembly/
Place angle brace (6) in place and install two hexagon head cap screws (7)
Angle brace (6)
in the bottom holes. Install four machine bolts (8), flat washer (9) and
Hexagon head cap
hexagon self-locking nuts (10). Tighten only slightly. Repeat procedure
screws (7)
for remaining bracket.
Machine bolts (8)
Flat washers (9)
Hexagon self-locking
nuts (10)
Slide loop clamp (11) around the plumbing assembly pipe (12) just below
Loop clamp (11)
connection. Position frame assembly (1) so loop clamp (11) will mate with
Plumbing assembly
tab on frame. Install hexagon head cap screw (13) and secure with
pipe (12)
hexagon self-locking nut (14).
Hexagon head cap
screw (13)
Begin to tighten all screws, bolts, and nuts (from 14 back to 4) until tight.
Hexagon self-locking
nut (14)