The unit is now ready to be returned to service.
and evenly to 150 inch pounds torque. Figure No. 54.
Check the condition of the column assembly, clean it,
and replace on the unit with two cap screws oriented as
before. Rotate the steering shaft while bringing the
surfaces into contact to allow splines to engage. Figure
No. 55. If in
doubt, follow the orientation as shown. Tighten cap screws
to 280 inch pounds. Figure No. 56.
To service earlier units, follow a similar procedure. In
units with a hat-shaped check plug, use gasket No. 20911
between the housing and the mounting plate. Insure that
each part is smooth and clean by rubbing on 400 grit
abrasive paper before cleaning for reassembly.
In units which have thin plastic gaskets at the meter
section seams a gasket MUST be used at each side of the
ring gear unless the entire gear set is replaced.
Replacement gear sets are sized so that the gasket should
NOT be used.