TM 3-6910-227-10
b. Hold the M256 kit with one hand at the bottom
You can run more than one test using one
case with the top case fastener facing away from you.
test bottle without introducing more simulant.
c. With the other hand, grasp the loose end of the
If necessary additional simulant can be added
to continue test without washing test bottle.
top case fastener. Using one continuous motion, pull
upward on the top case fastener which separates the
a. Perform the procedure of paragraphs 2-4 and
hook and pile fastener tape. Continue to pull up on the
top case fastener until the top case stops its upward
b. Pull off and discard the pull tab (marked 1) to
motion.
d. Pull the top case fastener away from you until
expose the lewisite detecting tablet (fig. 2-2).
c. Rub the top half of white paper side of lewisite
the top case is completely open.
tablet rubbing tab (marked 2) on lewisite detecting tablet.
e.  Remove a sampler-detector from M256 kit.
Repeat rubbing until mark is visible.
Read the instructions on both sides of protective bag
d. Hold the sampler-detector in the vertical position
before proceeding.
so that the ampoules are down.
f.  Check the discard date on protective bag to.
e. Finger-crush the two reagent ampoules (marked
make sure the discard date has not expired. If discard
3) one on each side of the center pockets. Do not crush
date has expired, discard the sampler-detector. Obtain
the two center ampoules in the center pocket (marked
another sampler-detector.
3). The ampoules to crush are indicated by asterisks on
g. Carefully tear open protective bag along the tear
line marked with arrows.
h. Remove sampler-detector from protective bag.
f. Rotate the sampler-detector until the test spots
are in a down position. Force the liquid from the two
Hold sampler-detector by hinged protective strip (fig. 2-2)
crushed ampoules through the formed channels to the
in the closed position.
test spots. Doing this makes sure that the test spots get
wet.
CAUTION
g. Check that hinged protective strip that is over the
Be careful not to touch the test spots.
test spots. Hold the sampler-detector horizontal with left
Touching the test spots could result in a
thumb over the center test spot.
false test.
h. Swing the hinged heater assembly away from
the blister agent test spot.
i. Swing the hinged heater assembly away from test
spots.  Discard two loose protective strips under the
WARNING
hinged heater assembly.
Wear your protective mask when operating the
j.  Thoroughly inspect the sampler-detector for
sampler-detector. The heater ampoules, when
damage; such as, missing components, broken or empty
broken, produce hot vapors which may cause
ampoules, obstructed formed channels, or cracked
injury to your eyes. Hold the sampler-detector at
plastic pockets. If any of these has occurred, discard
arms length, down, and away from your body
sampler-detector and repeat this preparation procedure
when breaking heater ampoules to prevent hot
with a new sampler-detector.
k. Swing the hinged heater assembly back over the
vapors from reaching your eyes.
test spots.
CAUTION
2-6. Testing Procedures for H, NA, and L Vapor Agents
Break only one green ampoule at a time
because, if two ampoules are broken, the blister
test cannot be completed.
NOTES
The following procedure is intended to
i.  Finger-crush one of the two green ampoules
instruct the user by providing him with an
(marked 4).
Immediately swing the hinged heater
unknown simulant on which to perform all the
assembly over the blister agent test spot. Vent vapor
tests on one sampler-detector.  If desired,
away from the operator's body. Leave the hinged heater
the instructor may elect to demonstrate one
assembly in place for 2 minutes.
test at a time. He should, therefore, prepare
j.  Swing the hinged heater assembly (after 2
only the appropriate test spot by following the
minutes has passed) and the hinged protective strip
applicable steps for that particular test.
away from the test spots.
Change 1 2-3