4240-01-055-1493)">
|
|
TM 3-4240-302-30&P-6
2-7. AIRFLOW VALVE (CONT).
LOCATION
ITEM
ACTION
INSTALLATION (CONT)
Airflow Valve
RFI filter FL1
5.
Place wires (18 and 25) in position in the
airflow valve (26).
6.
Solder wire (18) to normally closed (NC)
terminal on sensitive switch S2. Refer to wiring
diagram (p. 2-19).
7.
Install ground terminal lugs (16 and 17), using
screw (15) and nut (14).
8.
Install tiedown strap (11) using screw (13) and
nut (14). Secure the wire within the tiedown
strap.
9.
Solder wire (25) to normally closed (NC)
terminal on sensitive switch S1. Refer to wiring
diagram (p. 2-19).
10. Install ground terminal lug (24) using screw
(23) and nut (22).
11. Install tiedown strap (19) using screw (21) and
nut (20). Secure wires within tiedown strap.
12. Coat electrical connections with oil varnish
(item 3, app C).
2-14
|