2-7. AIRFLOW VALVE (CONT).
LOCATION
ITEM
ACTION
REMOVAL (CONT)
Airflow Valve
RFI filter FL1
5.
Cut tiedown strap (11). Remove nut (12), screw
(13), and tiedown strap (11).
6.
Remove nut (14), screw (15), and two
grounding terminal lugs (16 and 17) from
GRD 2.
7.
Tag and unsolder wire (18) from normally
closed (N C) terminal on 52 limit switch.
8.
Cut tiedown strap (19). Remove nut (20), screw
(21), and tiedown strap (19).
9.
Remove nut (22), screw (23), and grounding
lug (24) from GRD 3.
10. Tag and unsolder wire (25) from normally
closed (NC) terminal on S1 sensitive switch.
11. Remove RFI filter FL1 (9) from airflow valve
(26).
NOTE
Be sure to keep the old RFI filter FL1
with wires intact. It will be used as a
pattern for installing a new RFI filter
FL1.