TM 3-4240-201-13
Section II
MAINTENANCE ALLOCATION CHART
FOR
FILTER UNIT, GAS-PARTICULATE, HOSPITAL, SIX-IAN, 12 CFM, ABC-M7A1
SECTION II. MAINTENANCE ALLOCATION CHART
(1)
(2)
(3)
(4)
(5)
GROUP
FUNCTIONAL GROUP
MAINTENANCE FUNCTIONS
TOLS AND
REMARKS
NUMBER
COMPONENT ASSEMBLY
EQUIPMENT
100
HEADPIECE
Tester, Airflow, Gas-
Organizational mainten-
Particulate, Filter
ance personnel will use
Unit, FSN 6680-
tester to check for satis-
Headpiece, M18A1C
C
C
C
436-4212
factory output of filter
0.1
0.1
0.1
unit installation.
200
HOSE ASSEMBLIES
Tester will also be used
Hose assemblies
C
OO
in organizational pre-
0.1
0.3 0.4
ventive maintenance
check to determine when
to replace particulate
filter.
300
AIR PURIFIER
Instructions for use of
1
2
C
O
O
tester are provided with
Purifier, air, M2A2C
C
0.1
0.6
0.1
0.5
tester.
1. External inspection.
2. External cleaning.
3. Functional test.
Precleaner and housing
C
F
0
0
F
H
assembly
0.1 0.2 0.1
0.1
1.0 1.6
Precleaner, air purifier,
F
F'
F
F
M1A1
0.2 0.8
1.0
1.5
400
C
F
C
O
F
0.1 0.5 0.1
0.1
1.0
C-3