TM 3-4240-201-13
CHAPTER 2
OPERATING INSTRUCTIONS
Section I. CONTROLS AND INSTRUMENTS
2-1.
General
2-2.
Toggle Switch
a. Location. The toggle switch is located on the
The toggle switch is the only control for the filter unit.
There are no instruments required for the operation of
side of the transformer case.
b. Purpose.  The toggle switch is used by the
the filter unit.
operator (attendant) to turn the filter unit power supply on
and off.
Section II. OPERATION UNDER USUAL CONDITIONS
a. Preparation. The following preparations should
2-3.
General
be made by the attendant:
(1) Remove the headpiece from the carrier.
The filter unit is installed by organizational maintenance
(2) Screw the inlet adapter of the hose
personnel in a location convenient to the patients who
assembly into the inlet adapter mount of the headpiece.
are to be protected.
(3) Place the headpiece near the patient
ready for immediate use.
2-4.
Putting
Headpieces
on
Patients
and
(4) Make sure that the hose is long enough to
Operation
permit putting the headpiece on the bed patient without
difficulty (fig. 2-1).
WARNING
(5) Plug 115 vac power cable into 115v outlet
The mission oriented protective posture
and connect 24 vdc power cable to batteries.
(MOPP) (FM 21-40) directs that when a
b. Masking Procedure.
threat of a chemical attack exists, the
(1) Place the toggle switch on the transformer
attendant and the six patients must be
case in ON position.
masked beforehand to be safe.
(2) Make sure that air is being supplied to all
headpieces.
WARNING
(3) Place the headpiece over the patient's
Headpieces cannot be put on six
head with the eyepiece positioned over the patient's
patients by one attendant in the time the
eyes.
patients can be expected to hold their
(4) Pass the neck strap on the headpiece
breath.  Therefore, since some of the
around the patient's neck. Tie the strap tight enough to
patients may be able to put on their own
restrict flow of air around the patient's neck but not so
headpieces, they should be taught to do
tight as to cause him discomfort.
so. Also, patients should be taught to
help each other don the headpieces.
2-1