TM 3-4240-201-13
b. Use DD Form 6 (Report of Packaging and
Edgewood Arsenal, ATTN: SMUEA-DE-ET, Edgewood
Arsenal, MD 21010.
Handling Deficiencies) to report damaged or improper
d. Refer to TM 740-90-1 for administrative storage
shipment of materiel.
c. The  reporting  of  errors,  omissions,  and
instructions for this filter unit.
e. Refer to FM 5-25 and TM 9-1375-200 for
recommendations for improving this manual by the
destruction instructions on this equipment.
individual user is encouraged.
Reports should be
submitted on DA Form 2028 (Recommended Changes
to Publications) and forwarded direct to Commander,
Section II.
DESCRIPTION AND DATA
(2) Size 3 hose assembly. Each size 3 hose
1-3.
Use
assembly consists of a 9-foot airduct hose, two ratchet
clamps, one pulomatic plug, and one Y-fitting and
The filter unit adsorbs toxic gases, dusts, and aerosols
socket.
from the air and supplies purified respiratory air to six or
d. Air Purifier.  The M2A2 air purifier (fig. 1-4)
fewer hospital patients. These patients have wounds or
consists of a manifold assembly, a precleaner and
bandages on the neck, face, or head and cannot wear a
housing assembly, an M13 12 cfm particulate filter, an
conventional mask.
M12A1 12 cfm gas filter, and airflow control caps. The
manifold assembly closes the air outlet end and the end
1-4.
Description
plate closes the inlet end of the air purifier. The manifold
assembly has four (earlier models have three) pulomatic
a. General. The filter unit consists of the following:
sockets for attaching hose assemblies. The four sockets
headpiece, hose assembly, air purifier,  transformer,
are equipped with airflow control caps.  Each airflow
accessories, and repair kit. Air is drawn through intake
control cap has a ring in its middle which fits around a
holes in the air purifier where it is filtered and purified.
pulomatic socket. One end is a solid cap and the other
The purified air is blown through hoses to the
end has a hole in its center. The solid caps are used to
headpieces. Power to operate the purifier is controlled
prevent foreign matter or moisture from entering the gas
by a transformer unit.  The electrical power normally
filter when the hoses are not attached to the purifier. A
supplied to the transformer is 115 volt alternating current
solid end cap is snapped over the pulomatic socket that
(ac) with emergency 24 volt battery power. If the 115 volt
is not in use. The end of the airflow control cap with the
ac power fails, the transformer automatically switches to
small hole in it is snapped over a pulomatic plug on the
the standby 24 volt dc power source. Each headpiece is
manifold when a second pulomatic socket is not in use.
stored in a carrier when not in use.
This prevents excessive air pressure from building in the
b. Headpiece. The headpiece (fig. 1-2) consists of
two pulomatic sockets in use.
six M13A1 hospital filter unit headpieces and six M12
e. Transformer. The transformer (fig. 1-5) consists
hospital filter unit headpiece carriers.  The headpiece
of a step down power transformer, a case, three power
carrier is a plastic bag equipped with a buckle and a
cable assemblies, a relay, and a toggle switch.  The
strap.  When the headpiece is inside the carrier, the
transformer receives 115 volts ac input, which it steps
carrier is folded on the marked lines, rolled tightly, and
down to a 30 volts 3 amperes output. The transformer is
fastened with the strap and buckle. The headpiece is a
capable of operating on a 24 volts dc power source. The
hood that fits loosely over the patient's head. The plastic
case is marked to identify the three power cables as
headpiece consists of the hood,  inlet adapter mount,
follows: LEAD TO 115 V 60 HZ SUPPLY; LEAD TO 24
outlet valve, eyepiece, and strap. The strap provides the
V BATTERY; and LEAD
means for fastening the headpiece around the neck of
the patient as shown in figure 1-1.
c. Hoses. The hose assemblies (fig. 1-3) consist
of two size 3 hose assemblies and six size 2 hose
assemblies.
(1) Size 2 hose assembly. Each size 2 hose
assembly consists of a 6-foot airduct hose, two ratchet
clamps, a pulomatic plug, and an is: let adapter.