Section III. OPERATION UNDER USUAL CONDITIONS
2-8 INITIAL ADJUSTMENTS AND DAILY CHECKS.
2-9 OPERATING PROCEDURES.
The following procedures are for operating the Smoke Generator Set in usual conditions of temperatures
between 32F (0C) and 90F (32C). Starting procedures are the same for both smoke generators.
WARNING
Prolonged breathing of fog oil smoke may cause pneumonia. Stay out of
smoke or wear your protective mask as much of the time as possible while
operating your smoke generator.
HIGH INTENSITY NOISE is present during operation. Wear authorized
hearing protection within 25 feet while smoke generator is operating.
a. Starting.
CAUTION
Do not hold the FUEL, ENGINE, or FOG OIL switches in the START position
for more than 30 seconds or equipment will be damaged.
(1) Start vehicle engine. See vehicle operators manual.
(2) Set circuit breaker CB1(1) to ON.
(3) Set POWER switch (2) to ON. POWER indicator lights and air compressor starts.
(4) Hold FUEL switch (4) in START (up) position until FUEL indicator lights. After indicator lights,
release FUEL switch and allow it to move to RUN (center) position.
(5) Wait for AIR indicator to light. After AIR indicator lights, push PURGE pushbutton (5) for 3 seconds
to purge pulse jet engine. Wait for AIR indicator to light again.
Change 4