TM 3-1040-279-12&P
Table 2-1. Operator Preventive Maintenance Checks and Services (cont)
Not Fully
Location
Procedure
Item
Interval
Mission
Item to Check/
No.
Capable If:
Service
b. Remove refueling cap (4)
Fuel Cans
3
BEFORE,
on both 5-gallon fuel cans
AFTER
(cont)
(cont)
(5) and check for water or
dirt in fuel. Clean fuel can
and fuel can lid assembly
strainer screen, if con-
taminated.
c. Fill fuel cans to bottom of
BEFORE,
fill hole in fuel can lid
AFTER
assemblies with clean fuel
and secure refueling caps
(4).
Class III fog oil leaks are
a. Check for signs of leaks in
M54 Smoke
4
BEFORE,
present, or Class II and III fuel
all hoses, connectors, and
AFTER
leaks are present.
lines.
Hoses are torn, cracked, or
Check that hoses are
collapsed.
not torn, cracked,
twisted, or collapsed.
Cable connectors are broken.
b. Check that cable
BEFORE,
assemblies are correctly
AFTER
connected and tight.
Cable insulated is dry rotted,
Check cable insulation
cut, or worn to bare wire.
for dry rot, cuts, or
wear to bare wire.