TM 3-1040-214-12
from the agent delivery pipe. The cap is stowed on the
b. Tank Group.
coupling cap holder when the disperser is in use. A
hinged clamp is welded to both tanks and is used to hold
Weight
--------------------------------------- 42 lb
the pressure tank in place. The clamp is locked in place
Height
--------------------------------------- 27 in.
by a wing nut assembly.
Width
--------------------------------------- 20 in.
Depth
--------------------------------------- 11 in.
Pressure:
Pressure tank (max. efficiency) ----- 1,700 to 2.100 psi
assemblies. The carrier pack is attacked to the tubular
Agent tanks --------------------------------- 30 to 90 psi
frame with cotton cords. The upper shoulder straps are
Weight per filling (two tanks):
attached at one end to a metal strap welded to a bracket
CS1
--------------------------------------- 8 lb.
between the agent tanks. The lower shoulder straps, at
T1 (talc)--------------------------------------- 29 lb.
one end, are attached to the lower part of the tubular
frame.
The upper and lower shoulder straps are
c. Hose Group.
connected together by quick-release buckles. The body
straps are attached at one end of the tubular frame and
3
Weight
--------------------------------------- 1 /4 lb.
are connected together by a breakaway buckle. The
Length
--------------------------------------- 37 in.
carrier section provides a means for the operator to
conveniently carry the tank group on his back during use
d. Gun Group.
and operation of the disperser.
1
Weight
--------------------------------------- 3 /2 lb.
1-7. Identification Plates
Length
--------------------------------------- 26 in.
e. Packing Chest.
riveted to the valve body immediately above the trigger.
5
Length
--------------------------------------- 29 /8 in.
The plate contains pertinent information on the gun.
Width
--------------------------------------- 22 in.
3
Height
--------------------------------------- 14 /8 in.
riveted to the upper (shoulder) strap support located
1-9. Functioning
between the agent tanks. The plate contains pertinent
information on the agent tanks.
When the valve handle is turned counterclockwise, the
1-8. Tabulated Data
pressure tank valve opens, and pressurized air is
released from the pressure tank. Pressurized air passes
All data are approximate.
through the pressure tank valve and into the regulator
tube and pressure regulator, where the air pressure is
a. General.
reduced to operating pressure. The air then enters the
safety valve, which contains a disk in the safety head.
Range (in still air) ----------------------------------
40 ft.
This disk ruptures when air pressure in the safety valve
Duration of firing:
rises above 150 psi 25 psi. A check valve in the outlet
Single burst ---------------------------------
19 sec.
end of the safety valve closes when the disk bursts, and
Short burst (5- to 6-sec. duration) --
30 sec.
the agent is prevented from entering the atmosphere.
Pressure regulator setting-------------
40 10 psi
Air in the safety valve flows into the safety valve adapter
Operating pressure ----------------------
30 to 90 psi
through both hose assemblies, cap and pipe assemblies,
Weight (empty) ----------------------------
47 lb.
the diffusion tube, and mixes with the agent in the agent
Weight (in packing chest) -------------
100 lb.
tanks. When the trigger is pressed, air and agent enter
Weight (filled):
the tank connector, hose assembly, and gun barrel and
CN1, DM1, or CN1-DM1
go into the atmosphere. When the shutoff valve handle
Mixture ----------------------------------
67 lb.
is turned counterclockwise, the shutoff valve opens and
CS1
---------------------------------------
55 lb.
vents air pressure through the diffusion pipe, vent tube,
T1 (talc)---------------------------------------
76 lb.
and into the atmosphere.
1-9
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |