TM 11-6665-230-12
CHAPTER 2
OPERATING INSTRUCTIONS
SECTION I DESCRIPTION AND USE OF OPERATOR'S CONTROLS AND INDICATORS
2-1. OPERATOR CONTROLS AND INDICATORS (fig. 2-1) The six position function switch peforms the
following  functions:
Radiacmeter Function
Switch Position
No power or removal of power
OFF
BAT CON D
Connects battery to meter for battery checks
NOTE
The next 4 switch positions connect the batteries to operate
the radiacmeter in different ranges of sensitivity.
500
First scale on the meter; used to measure strong radiation
levels up to 500 mR/hr. (5000 u Gy (mrad)/hr)
Second scale on the meter; used to measure radiation levels
50
up to 50 mR/hr. (500 u Gy (mrad)/hr)
Third scale on the meter; used to measure weak radiation
5
levels up to 5 mR/hr. (50 u Gy (mrad)/hr)
Lowest on the meter; used to measure weak radiation levels
0.5
up to 0.5 mR/hr. (5 u Gy (mrad)/hr)
SECTION II PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS)
2-2. GENERAL
NOTE
To be sure that the Radiac Set is always ready for use, you must do PREVEN-
TIVE MAINTENANCE CHECKS AND SERVICES (PMCS).
a. Before You Operate. Perform your B PMCS to be sure that the Radiac Set is always ready for use.
Always keep in mind the CAUTIONS and WARNINGS that appear in this manual (fig. 2-1).
b. While You Operate. Perform your D PMCS. This should help you spot small troubles before they
become big problems. Always keep in mind the CAUTIONS and WARNINGS that appear in this manual.
c. After You Operate. Perform your A PMCS. This should help you keep the Radiac Set in top shape.
d. When The Radiac Set Fails To Operate. Follow the maintenance instructions in Chapter 3.
Report any deficiencies using the proper forms in accordance with DA Pam 738-750
2-3. PMCS PROCEDURES (Table 2-1)
a. The PROCEDURES column in your PMCS chart instructs you to "CHECK AND HAVE REPAIRED
OR ADJUSTED AS NECESSARY". Carefully follow these instructions and if tools are needed or the chart
instructions tell you, get organizational maintenance to do the necessary work.
2-1

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business