Control settings
Test procedure
Performance Standard
Equipment under test
Test equipment
Step
a. 1.65 sec maximum.
a. Continually press, with slight pauses,
4
...............................................................
transponder test set PUSH-TO
TEST switch, while rotating
A N / A P M - 2 7 0 ( V ) SPACING
PULSE 2 control clockwise until a
just reject condition is obtained
then counterclockwise for an accept
condition. Note spacing between
first and second pulses.
b. 1.35 sec maximum.
b. Repeat a above, except turn SPAC-
ING PULSE 2 control counter-
..
clcokwise for REJECT and then
clocwise for ACCEPT.
c. 3.45 se minimum, 3.75 sec
C. Repeat a and b above, except operate
maximum.
A N / A P M - 2 7 0 ( V ) SPACING
PULSE 3 control.
|