Control settings
Normul indication
Procedure
Euipment under test
Test equipment
Step
c. Increase AN/UPM-137A rf signal c. None.
gemerator OUTPUT ATTEN 0-100
dBm control to -6 dBm.
a. None.
a. Disconnect cable at AN/UPM-137A
PUSH TO TEST: LOCK
Same as step 2 . . . . . . . . . . . . . . . . . . . .
4
rf signal generator SIG GEN
IN/OUT 0.5-50W jack and connect
to AN/APM-270(V) RF IN jack.
b. None.
VERTICAL CHAIN A-VIDEO IN
jack to DET VIDEO jack of
AN/APM-270(V).
c. None.
controls for clear display on CHAN
A.
d. 36 pulses present: 1 pulses, a
vacant position. andld 32 pul-
controls as necessary until one com-
ses.
plete group of challenge video pul-
ses is observed. Count number of
pulses.
e. 10% maximum difference in
e. Measure amplitude of first and last
amplitude between two
pulse and determine percentage of
pulses.
difference.
NOTE
Adjust AN/UPM-137A oscillo-
scope controls.
f. 2 0 . 0 7 s e c .
f. Measure Spacing between leading
edges first and second pulses.
g. 0.5 0.2 sec.
g. Measure pulse width of first pulse at
50% point of amplitude.
h. Fifth pulse position occupied.
h. Set test ISLS switch to ON. Note
whether a pulse, having similar am-
plitude as other, occupies, fifth
pulse position.
i. Measure pulse spacing with respect to
i. 8 0.15 sec.
first pulse.
j. Measure ISIS pulse width at 50% j. 0.5 0.1 sec.
point.
h. Pulse amplitude decreases to
k. Set Teat ISLS switch to OFF. Note
whether amplitude of fifth pulse
low amplitude.
decreases.
5
Same as step 2 . . . . . . . . . . . . . . . . . . . PUSH TO TEST
a. Disconnect cable at RF IN jack of a. None,
AN/APM-270(V) and connect to
Continually press and release to ob-
AN/UPM-137A rf signal generator
serve specific conditions.
RF SIG GEN IN/OUT 0.05-50W
jack.
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |