5-6. Receiver Frequency, S e n s i t i v i t y ,
(5) Comparator, Frequency CM-77A/USM.
and Bandwidth Test
(6) Oscilloscope, AN/USM-281A.
a. Test Equipment Required.
(1) Modulator MD-796
b. Test Connection and Conditions. Connect the
(2) Generator, Signal AN/URM-64A.
equipment as shown in figure 5-4. The modulator
(3) Frequency Meter AN/USM-207.
and the AN/URM-64A shall be connected as speci-
(4) Test Set, Radar AN/UPM-98.
fied in c below.